Testa att söka på nyckelord, orderkod eller produktkod, eller serienummer t.ex. ”CM442” eller ”teknisk information”
Enter at least 2 characters to start the search.
Bioprocessing Raman spectroscopy calibration and verification kit for the Raman flow assembly

Raman calibration and verification kits

Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability

KRCAL
Please Wait (spinning wheel)
Laddar pris
Pris ej tillgängligt för tillfället
Price on request
Aktiverar pris
pris: ange information
from CHF ??.-
Filtrera mät-/applikationsuppgift
Mät-/applikationsuppgift

Konfigurera för att ladda ner denna produkts CAD-ritningar

  • Mätprincip

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-10 (with bio multi optic)

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm

  • Mätprincip

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-10 (with Raman flow bench)

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm

  • Mätprincip

    Raman spectroscopy

  • Temperature

    Operating:
    0 to 40 °C /32 to 104 °F
    Storage:
    -15 to 50 °C / 5 to 122 °F

  • Relative humidity

    Storage:
    < 80 % Non-Condensing

  • Unit dimensions (width x height x depth)

    Kit: 235 x 192 x 85 mm
    9.3 x 7.6 x 3.4 inch

  • Weight

    Kit: 1.5 kg / 3.3 lbs

  • Sampling probe compatibility

    Raman Rxn-46

  • Spectral intensity reference

    Calibration Reference Standard

  • Spectral intensity output repeatability (at time of certification)

    < ±2 %

  • Long term spectral uncertainty (at any wavelength)

    ±6.05 %

  • Spectral intensity calibration range

    CRS-785: 790.7 to 1074.5 nm