En överblick över specifikationer
-
Measured Variables
Concentration
Dew Point
Cell Pressure
Cell Temperature -
Hazardous area approvals
CSA Class I, Division 2
CSA Class I, Zone 2
Applikationsområde
Using patented tunable diode laser spectroscopy (TDLAS) technology, the SS500 analyzer is an economical choice for measuring H2O concentration in natural gas without coming into physical contact with the stream. The result is a sensor that does not suffer from contamination or drift due to vapor impurities such as glycol, methanol, or amines.
Natural gas quality measurements in production, storage, transportation, and distribution
Monitoring for natural gas pipelines, processing plants, compressor stations, gathering sites, and distribution quality
Suitable for use as a check-measurement device
Measurable ranges of up to 0-250 lb/mmscf (0-5275 ppm) H2O
Fördelar
Economical real-time moisture measurements
Virtually maintenance-free
Reliable in harsh environments
Fast and accurate with no wet-up or dry-down delays
No contamination or drift due to vapor impurities such as glycol, methanol, amines, hydrogen sulfide, or mercaptans
NIST-traceable calibration with analog and serial outputs for remote monitoring
CSA certified for CSA Class 1, Division 2 or Class 1, Division 1
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
-
Teknisk information (TI)
SS500/SS500XP TDLAS Gas Analyzer
System design and specifications for theSS500/SS500XP TDLAS Gas
AnalyzerSpråk:
Engelska
Version:
14/09/2021
Filstorlek:
1.1 MB
Filnamn:
TI01642CEN_01.21.pdf
-
-
-
Användarinstruktion (BA)
TDL measurement cell Operating Instructions
Operation and maintenance details for TDLAS gas analyzer
measurement cellsEN SV 02/08/2024Språk:
Engelska
Version:
02/08/2024
Filstorlek:
1.3 MB
Filnamn:
BA02188CEN_0224.pdf
-
-
-
Användarinstruktion (BA)
SS500/SS2000 TDLAS gas analyzer Operating Instructions
Commissioning, operation, and maintenance details for the
SS500/SS2000 TDLAS gas analyzerSpråk:
Engelska
Version:
29/10/2024
Filstorlek:
4.2 MB
Filnamn:
BA02182CEN_0224.pdf
-
-
-
Användarinstruktion (BA)
SS500XP/SS2000XP TDLAS Gas Analyzer
Commission, operation and maintenancedetails for the
SS500XP/SS2000XP TDLAS Gas AnalyzerSpråk:
Engelska
Version:
17/09/2021
Filstorlek:
4.7 MB
Filnamn:
BA02183CEN_01.21.pdf
-
-
-
Enhetsparameter (GP)
HC 12 firmware Description of device parameters
Expert-level description and operational information for
device parametersSpråk:
Engelska
Version:
02/08/2024
Filstorlek:
2.1 MB
Filnamn:
GP01181CEN_0224.pdf
-
-
-
Installationsanvisningar (EA)
TDLAS cell assembly mirror cleaning Installation Instructions
Instructions for cleaning the 0.1 m, 0.8 m, 8 m/28 m
measurement cell mirror for multiple product platformsSpråk:
Engelska
Version:
29/07/2024
Filstorlek:
404.3 KB
Filnamn:
EA01381CEN_0224.pdf
-
-
-
Installationsanvisningar (EA)
Installation Instruction
Installation Instruction for SS2000XP Floating Ground Re-Work Kit
Språk:
Engelska
Version:
15/02/2022
Filstorlek:
1.8 MB
Filnamn:
EA01421CEN 0122.pdf
-
-
-
Ex-säkerhetsinstruktion (XA)
SS500/SS2000/SS3000, SS500e/SS2000e/SS3000e and SS500XP/SS2000XP Safety Instruction
Safety Instructions for the SS500/SS2000/SS3000,
SS500e/SS2000e/SS3000e and SS500XP/SS2000XP TDLAS Gas AnalyzersSpråk:
Engelska
Version:
04/10/2021
Filstorlek:
2 MB
Filnamn:
XA02744CEN_01.21.pdf
-
-
-
Specialdokumentation (SD)
AMS100 Software Operating Instructions
Instructions for operating the AMS100 software as an
alternative method for TDLAS gas analyzer system configurationSpråk:
Engelska
Version:
10/05/2023
Filstorlek:
1.3 MB
Filnamn:
SD02863CEN_0223.pdf
Firmware:
SSI v1.4
-
-
-
Specialdokumentation (SD)
Validation of TDLAS gas analyzers Special Documentation
Description, guidelines, and procedure for validation of TDLAS
gas analyzersSpråk:
Engelska
Version:
29/07/2024
Filstorlek:
2.4 MB
Filnamn:
SD03286CEN_0124.pdf
-