Testa att söka på nyckelord, orderkod eller produktkod, eller serienummer t.ex. ”CM442” eller ”teknisk information”
Enter at least 2 characters to start the search.
Hygienic thermometer iTHERM TM412 - Imperial version US Style

iTHERM ModuLine TM412
Hygienic modular thermometer

Imperial RTD thermometer with or without thermowell for hygienic applications 

TM412
Please Wait (spinning wheel)
Laddar pris
Pris ej tillgängligt för tillfället
Price on request
Aktiverar pris
pris: ange information
from CHF ??.-
Filtrera mät-/applikationsuppgift
Mät-/applikationsuppgift

Konfigurera för att ladda ner denna produkts CAD-ritningar

  • Mätprincip

    Resistance Temperature Detector

  • Characteristic / Application

    imperial style
    modular temperature assembly
    hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA)
    hygienic process connections
    with neck
    suitable for hazardous areas
    incl. protection tube
    iTHERM QuickSens for fastest response time
    iTHERM StrongSens for most robust design
    iTHERM QuickNeck for easy and cost saving recalibration

  • Thermowell / protection tube

    without
    incl. thermowell
    incl. Tee-/elbow thermowell

  • Insert / probe

    mineral insulated (MI), flexible
    pipe version, isolated wires, not flexible

  • Outer diameter protection tube / Insert

    1/4'' (6,35 mm)
    3/8'' (9,53 mm)
    1/2" (12,7 mm)

  • Max. immersion length on request

    48"

  • Material protection tube/ thermowell

    316L

  • Process connection

    Weld-in adapter
    Tri-clamp
    Clamp-connections according to ISO2852
    G3/4" Liquiphant
    G1" Liquiphant
    Varivent
    T- and elbow thermowell

  • Tip shape

    straight
    reduced

  • Surface roughness Ra

    30 μin (0,76 μm)
    15 μin (0,38 μm )
    15 μin (0,38 μm) electropolished

  • Operating temperature range

    PT100 WW:
    -200 °C … 600 °C
    (-328 °F … 1.112 °F)
    iTHERM StrongSens:
    -50 °C … 500 °C
    (-58 °F … 932 °F)
    iTHERM QuickSens:
    -50 °C … 200 °C
    (-58 °F … 392 °F)
    PT100 TF:
    -50 °C … 200 °C
    (-58 °F … 392 °F)

  • Max. process pressure (static)

    at 20 °C: 40 bar (580 psi)

  • Accuracy

    class B acc. to IEC 60751
    class A acc. to IEC 60751
    class AA acc. to IEC 60751

  • Response time

    depending on configuration
    iTHERM QuickSens: t90 = 1,5 s
    iTHERM StrongSens: t90 = 9,5 s

  • Integration head transmitter

    yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Ex - approvals

    ATEX II 3 G Ex nA IIC T6, II3D
    CSA General Purpose, CSA C/US
    CSA C/US IS, NI I/1+2/A-D
    CSA NI I/2/A-D
    CSA IS, NI I/1+2/A-D
    FM NI I / 2/A-D
    FM IS, NI I/1+2/A-D
    ATEX IECEx II1G Ex ia IIC T6 Ga
    FM+CSA IS, NI I/1+2/A-D
    ATEX IECEx II1/2D Ex tb IIIC Da/Db
    ATEX IECEx II1/2G Ex ia IIC T6 Ga/Gb
    ATEX IECEx II1/2D Ex ia IIIC Da/Db

  • Certification

    SIL (transmitter only)