Testa att söka på nyckelord, orderkod eller produktkod, eller serienummer t.ex. ”CM442” eller ”teknisk information”
Enter at least 2 characters to start the search.
Pt100 RTD thermometer TST310 temperature cable probe

iTHERM CableLine TST310
Cable probe

Metric RTD thermometer with connecting cable for use in many process and laboratory applications

TST310
Please Wait (spinning wheel)
Laddar pris
Pris ej tillgängligt för tillfället
Price on request
Aktiverar pris
pris: ange information
from CHF ??.-
Filtrera mät-/applikationsuppgift
Mät-/applikationsuppgift

Konfigurera för att ladda ner denna produkts CAD-ritningar

  • Mätprincip

    Resistance Temperature Detector

  • Characteristic / Application

    metric style
    cable probe
    suitable for hazardous areas
    process connection as compression fitting

  • Thermowell / protection tube

    without (not intended to use with thermowell)

  • Insert / probe

    mineral insulated (MI), flexible

  • Outer diameter protection tube / Insert

    3,0 mm (0,12'')
    6,0 mm (0,24'')

  • Max. immersion length on request

    up to 10.000,00 mm (393,70'')

  • Material protection tube/ thermowell

    1.4404 (316L)
    1.4571 (316Ti)

  • Process connection

    male thread:
    G1/4"
    G1/2"
    M10x1
    M8x1
    compression fitting:
    G1/8"
    G1/4"
    G1/2"
    NPT1/4"
    NPT1/2"
    M10x1
    M8x1

  • Tip shape

    straight

  • Operating temperature range

    PT 100:
    -200 °C ...600 °C
    (-328 °F ...1.112 °F)

  • Max. process pressure (static)

    at 20°C: up to 75 bar (depending on the process connection)

  • Accuracy

    class A acc. to IEC 60751
    class B acc. to IEC 60751
    class AA acc. to IEC 60751

  • Response time

    t50 = 3 s
    t90 = 6 s

  • Integration head transmitter

    no

  • Ex - approvals

    ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6
    ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6
    ATEX II1G Ex ia IIC T6
    ATEX II 3 G Ex nA IIC T6, II3D
    NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450
    EAC Ex ia
    UK II1G Ex ia IIC T6 Ga
    UK II1/2D Ex ia IIIC Da/Db, II1G Ex ia IIC T6 Ga
    UK II1D Ex ia IIIC Da, II1G Ex ia IIC T6 Ga
    UK II 3 G Ex nA IIC T6 Gc, II3D Ex tc IIIC Dc
    IECEx Ex ia IIC T6 Ga
    NEPSI Ex nA IIC T6