En överblick över specifikationer
-
Accuracy
repeatablity 0,1%
-
Process temperature
-80°C...200°C
-112°F...392°F -
Process pressure / max. overpressure limit
Vacuum ... 100 bar
(Vaccum ... 1450 psi) -
Max. measurement distance
0.42 m ... 10.0 m
(1.38 ft ... 33 ft) -
Main wetted parts
Insulation material: FEP,PFA
316L
Applikationsområde
Liquicap FMI52 is a reliable fully insulated rope probe for continuous level monitoring in liquids, particularly in small tanks, build-up forming media and extremely high temperatures - especially for large measuring ranges. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.
Device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.
Process connections: Flanges and threads
Process pressure: Vacuum to +100bar (vacuum to 1,450psi)
Measuring range: 0.42 to 10.0m (1.38 to 33ft)
Temperature: -80 to +200°C (-112 to +392°F)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Fördelar
Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508
Reliable and universal application thanks to wide range of certificates and approvals
No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higher
Material in contact with the process made of corrosion-resistant material
Menu-guided local configuration via plain text display (optional)
Two-stage overvoltage protection
Videor
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
Föregångare
-
-
Teknisk information (TI)
Liquicap M FMI52
Engelsk version - 04/2021
Capacitive
EN SV 01/04/2021Språk:
Engelska
Version:
01/04/2021
Filstorlek:
1.4 MB
Filnamn:
TI01521FEN_0221.pdf
-
-
-
Installationsanvisningar (EA)
Cable for separate version Installation instruction
Engelsk version - 04/2012
Liquicap M/ Solicap M (separate version)
EN SV 12/04/2012Språk:
Engelska
Version:
12/04/2012
Filstorlek:
585 KB
Filnamn:
EA0012FA2_1108.pdf
-
-
-
Teknisk information (TI)
Liquicap M FMI52
Capacitive
EN SV 01/04/2021Språk:
Engelska
Version:
01/04/2021
Filstorlek:
1.4 MB
Filnamn:
TI01521FEN_0221.pdf
-
-
-
Teknisk information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN SV 25/03/202415/09/202328/10/202130/07/202119/06/2020Språk:
Engelska
Version:
25/03/2024
Filstorlek:
1.1 MB
Filnamn:
TI00426FEN_2524.pdf
-
-
-
Teknisk information (TI)
Technical Information Liquicap M FMI51, FMI52
Capacitance level measurement
For continuous measurement in liquidsEN SV 22/06/201728/08/201212/01/201104/04/200701/09/2006Språk:
Engelska
Version:
22/06/2017
Filstorlek:
1.5 MB
Filnamn:
TI00401FEN_1517.pdf
-
-
-
Användarinstruktion (BA)
Liquicap M FMI52 HART
Capacitive
EN SV 01/04/202123/03/2020Språk:
Engelska
Version:
01/04/2021
Filstorlek:
2.3 MB
Filnamn:
BA02021FEN_0221.pdf
-
-
-
Användarinstruktion (BA)
Liquicap M FMI52 PFM
Capacitive
EN SV 01/04/202123/03/2020Språk:
Engelska
Version:
01/04/2021
Filstorlek:
1.5 MB
Filnamn:
BA01986FEN_0221.pdf
-
-
-
Användarinstruktion (BA)
Operating Instructions Liquicap M FMI51, FMI52 FEI50H HART
Capacitive level measurement
EN SV 22/06/201712/01/201130/01/200719/12/2005Språk:
Engelska
Version:
22/06/2017
Filstorlek:
2.1 MB
Filnamn:
BA00298FEN_1417.pdf
-
-
-
Användarinstruktion (BA)
Liquicap M FMI51, FMI52 FEI57C PFM Operating Instructions
Capacitance level measurement
Valid as of software version:
FW: V 01.00.00
HW: V 01.00EN SV 22/06/201712/01/201127/07/200719/12/2005Språk:
Engelska
Version:
22/06/2017
Filstorlek:
1.3 MB
Filnamn:
BA00297FEN_1417.pdf
-
-
-
Kortfattad instruktion (KA)
Liquicap M FMI52 HART
Kapacitiv
EN SV 01/08/202101/04/202101/02/2021Språk:
Svenska
Version:
01/08/2021
Filstorlek:
1.2 MB
Filnamn:
KA01454FSV_0321.pdf
-
-
-
Kortfattad instruktion (KA)
Liquicap M FMI52 PFM
Kapacitiv
EN SV 01/09/202101/04/202101/02/2021Språk:
Svenska
Version:
01/09/2021
Filstorlek:
849.4 KB
Filnamn:
KA01455FSV_0321.pdf
-
-
-
Installationsanvisningar (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction
Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
EN SV 09/08/2012Språk:
Engelska
Version:
09/08/2012
Filstorlek:
158.7 KB
Filnamn:
EA01049FA2_01.12.pdf
-