Ramanspektroskopi – avancerad optisk analysteknik
Förbättra anläggningssäkerheten, säkerställ produktkvaliteten och optimera driften. Ramanspektroskopi mäter sammansättningen och molekylstrukturen i dina prover från labb till process i realtid.
Raman Rxn-10 probe
Metal: C276 alloy as standard (316L stainless steel or Grade 2 titanium upon request)
Window: high-purity sapphire, proprietary compression fit non-brazed design
The fixed focus design of the Raman immersion optic provides long-term measurement stability along with superior signal performance which is essential for transferable, high-performance Raman measurements. Compatible with the Rxn-10 probe, the immersion optic uses no movable parts so it is always in focus. The Raman immersion optic is well-suited for use in reaction vessels, laboratory reactors, or process streams, and its wettable components resist corrosion in harsh environments.
Pharmaceutical: drug substance unit operations, reaction analysis, crystallization, end-point detection, solvent swaps
Chemical: material identification, reaction analysis, polymerization, cross-linking, blending
Food & Beverage: blending, purification, natural and synthetic components
Development laboratory: versatile in situ analysis, feasibility studies, model development (or similar)
Ideal for quick measurements of liquids, slurries, and semi-solids in a laboratory setting
Superior signal performance
Available in 1/4” and 1/2” diameters
No user-adjustable parts
Wettable components resist corrosion in harsh environments (including acidic solutions)
High-end produkter
Tekniska egenskaper
Enkelhet
Standardprodukter
Tekniska egenskaper
Enkelhet
Specialprodukter
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | SV | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Språk: |
Engelska |
Version: |
31/05/2023 |
Filstorlek: |
467.9 KB |
Filnamn: |
TI01635CEN_0322.pdf |
System design and specifications for the Raman Rxn-10 probe
EN | SV | ||
08/09/2025
|
|
|
|
13/11/2024
|
|
|
|
31/05/2023
|
|
|
|
13/09/2022
|
|
|
|
08/09/2021
|
|
|
Språk: |
Engelska |
Version: |
08/09/2025 |
Filstorlek: |
949 KB |
Filnamn: |
TI01629CEN_0525.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | SV | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
|
14/09/2021
|
|
|
Språk: |
Engelska |
Version: |
31/05/2023 |
Filstorlek: |
1.8 MB |
Filnamn: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
EN | SV | ||
08/09/2025
|
|
|
|
02/12/2024
|
|
|
|
31/05/2023
|
|
|
|
13/09/2022
|
|
|
|
08/09/2021
|
|
|
Språk: |
Engelska |
Version: |
08/09/2025 |
Filstorlek: |
1.8 MB |
Filnamn: |
BA02160CEN_0525.pdf |
Quick start guide for the Raman Rxn-10 probe
EN | SV | ||
02/12/2024
|
|
|
|
31/05/2023
|
|
|
|
13/09/2022
|
|
|
|
08/09/2021
|
|
|
Språk: |
Engelska |
Version: |
02/12/2024 |
Filstorlek: |
1.6 MB |
Filnamn: |
KA01546CEN_0424.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | SV | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
|
14/09/2021
|
|
|
Språk: |
Engelska |
Version: |
31/05/2023 |
Filstorlek: |
1 MB |
Filnamn: |
KA01551CEN_0322.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
Språk: |
Engelska |
Version: |
26/06/2025 |
Filstorlek: |
363.4 KB |
Filnamn: |
PU01611CEN_0125.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
Språk: |
Engelska |
Version: |
19/04/2022 |
Filstorlek: |
1.1 MB |
Filnamn: |
PU01447CEN_0222.pdf |
ライフサイエンス産業向けラマン分光法アプリケーションノート(
ラマンRxn2アナライザー、ラマンRxn4アナライザー、Rxn-10プロー
ブ、Rxn-20プローブ、Rxn-45プローブ、Rxn-46プローブ、プローブ
オプティックアクセサリ(bIOオプティック、シングルユース向け
ラマンオプティックシステム/SUB、浸漬オプティック、非接触オプ
ティック)。
Språk: |
Japanska |
Version: |
02/08/2024 |
Filstorlek: |
1.4 MB |
Filnamn: |
PU01447CJA_0222_Raman_App_Guide_for_LifeScience.pdf |
Ein Leitfaden zu unseren Anwendungshinweisen zur
Raman-Spektroskopie für die Life-Science-Industrie
(Raman Rxn2-Analysator, Raman Rxn4-Analysator,
Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde,
Rxn-46-Sonde und Zubehör für Sondenoptiken
(blO-Optic, Raman- Single Use-Optiksystem
/ SUB, Immersionsoptik, berührungslose Optik)
Språk: |
Tyska |
Version: |
24/09/2025 |
Filstorlek: |
1.4 MB |
Filnamn: |
PU01447CDE_0222_Raman-Anwendungsleitfaden_LSI_web.pdf |