Testa att söka på nyckelord, orderkod eller produktkod, eller serienummer t.ex. ”CM442” eller ”teknisk information”
Enter at least 2 characters to start the search.
Gamma Source FSG60 - Radiometric measurement

Radiometric level and
density measurement
Gamma Source FSG60

Gamma radiation source (137Cs) for radiometric level, point level, density and interface measurement

FSG60
Please Wait (spinning wheel)
Laddar pris
Pris ej tillgängligt för tillfället
Price on request
Aktiverar pris
pris: ange information
from CHF ??.-
Filtrera mät-/applikationsuppgift
Mät-/applikationsuppgift

Konfigurera för att ladda ner denna produkts CAD-ritningar

  • Mätprincip

    Radiometric

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification C66646 ISO 2919

  • Ambient temperature

    -20°C ... +250 °C
    (-4°F ... 482 °F)

  • Process pressure / max. overpressure limit

    Any

  • Pressure measuring range

    Any

  • Components

    Installed in source container

  • Mätprincip

    Radiometric

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification C66646 ISO 2919
    Activity calculation with
    Applicator

  • Ambient temperature

    -20°C ... +250 °C
    (-4°F ... 482 °F)

  • Process pressure / max. overpressure limit

    Any

  • Components

    Installed in source container

  • Mätprincip

    Radiometric Limit

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification C66646 ISO 2919
    Activity calculation with
    Applicator

  • Ambient temperature

    -20°C ... +250 °C
    (-4°F ... 482 °F)

  • Process pressure / max. overpressure limit

    Any

  • Components

    Installed in source container

  • Mätprincip

    Radiometric Limit

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification C66646 ISO 2919
    Activity calculation with
    Applicator

  • Ambient temperature

    -20°C ... +250 °C
    (-4°F ... 482 °F)

  • Process pressure / max. overpressure limit

    Any

  • Components

    Installed in source container

  • Mätprincip

    Radiometric Density

  • Characteristic / Application

    Source
    Isotope: Caesium 137
    Half-life: 30 years

  • Ambient temperature

    -20 °C ... +250 °C

  • Specialities

    Double seal
    Steel: 1.4541 (321 S 18)
    Classification: C66646 ISO 2919
    Activity calculation with
    Applicator

  • Components

    Installed in source container