©Endress+Hauser
©Endress+Hauser
Applikationsområde
CYK10 guarantees absolute water-proof connection of Memosens sensors to the transmitter. Its inductive coupling shows no contact corrosion and guarantees galvanic isolation of transmitter and medium. Simply forget about limited cable length, interfering potentials or moisture and benefit from completely safe and reliable signal transmission.
The Memosens data cable CYK10 is applied in Memosens systems measuring the following parameters:
Fördelar
Maximum process safety through non-contact, inductive and digital signal transmission: No contact corrosion, absolutely watertight, no interference potential.
Increased availability of the measuring point: Digital data transmission provides an automatic error message if the signal is lost.
More flexibility in plant planning and installation: Cable length up to 100 m is possible.
Approved for hazardous area use.
Köp produkten som en del av ett paket
Enkla produkter
Enkla att välja, installera och använda
Tekniska egenskaper
Enkelhet
Standardprodukter
Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
High-end produkter
Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
Specialprodukter
Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
FLEX urvalet
Tekniska egenskaper
Enkelhet
Fundamental urvalet
Möt dina grundläggande mätbehov
Tekniska egenskaper
Enkelhet
Lean urvalet
Hantera dina kärnprocesser med enkelhet
Tekniska egenskaper
Enkelhet
Extended urvalet
Optimera dina processer med innovativa teknologier
Tekniska egenskaper
Enkelhet
Xpert urvalet
Hantera dina mest utmanande applikationer
Tekniska egenskaper
Enkelhet
Kundcase
An automated system for pH measurements at AVR
AVR Waste in Botlek, Rotterdam, processes up to 1.7 million tons of residual waste per year. Discover how they optimized their pH measurement thanks to Endress+Hauser
Läs hela berättelsen
Pure high quality beer and clean wastewater
Discover how Heineken meets all regulations to protect the brazilian environment with the Viomax CAS51D digital nitrate or SAC sensor from Endress+Hauser.
Läs hela berättelsen
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Measuring range
High impedance cable not necessary
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Process pressure
max. 50 bar/725 psi at 135°C/275°F.
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals.
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter.
Characteristic
Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Mätprincip
Amperometric oxygen measurement
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 ... 135 °C (-13 ... 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Additional certifications
Also available as TÜV approved SIL version
Mest nedladdade
Technical Information
Memosens measuring cable and installation
accessories
Engelsk version - 12/2011
CYK10 / CYK11
EN
SV
CS DE ES FR IT NL PL RU
01/12/2011
01/11/2001
Språk:
Engelska
Version:
01/12/2011
Filstorlek:
718.3 KB
Filnamn:
TI00118CEN_1311.pdf
CYK10, CYK11
Technical Information
Engelsk version - 12/2011
Memosens measurement cables
Språk:
Engelska
Version:
01/12/2011
Filstorlek:
718.3 KB
Filnamn:
TI01477C_TI00118CEN_1311.pdf
53 dokument
Technical Information
Memosens measuring cable and installation
accessories
CYK10 / CYK11
EN
SV
Tjeckiska Tyska Spanska French Italienska Holländska Polska Ryska
01/12/2011
01/11/2001
Språk:
Engelska
Version:
01/12/2011
Filstorlek:
718.3 KB
Filnamn:
TI00118CEN_1311.pdf
CYK10, CYK11
Technical Information
Memosens measurement cables
EN
SV
Tyska French Ryska
01/12/2011
Språk:
Engelska
Version:
01/12/2011
Filstorlek:
718.3 KB
Filnamn:
TI01477C_TI00118CEN_1311.pdf
EN
SV
Bulgariska Tjeckiska Danska Tyska Grekiska Spanska Estniska Finska French Kroatiska Ungerska Indonesiska Italienska Japanska Koreanska Lithuanian Latvian Holländska Norska Polska Portugisiska Rumänska Ryska Slovakiska Slovenska Thailändska Turkiska Kinesiska
08/12/2021
28/02/2018
06/07/2016
28/08/2012
01/11/2011
Språk:
Svenska
Version:
08/12/2021
Filstorlek:
660.3 KB
Filnamn:
BA00118CSV_0520-00.pdf
XA Memosens data cable CYK10
Safety instructions for electrical apparatus in explosion-hazardous areas
EN
SV
Portugisiska
23/09/2024
Språk:
Engelska
Version:
23/09/2024
Filstorlek:
513 KB
Filnamn:
XA03307CEN_0124-00.pdf
FM IS Cl. I Div. I Gr. A, B, C and D Safety instructions for electrical apparatus in explosion-hazardous areas
Språk:
Engelska
Version:
15/03/2022
Filstorlek:
503.5 KB
Filnamn:
XA02846CEN_0122-00.pdf
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safetyinstructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN
SV
Tyska French
11/11/2016
31/12/2011
01/04/2009
Språk:
Engelska
Version:
11/11/2016
Filstorlek:
3.7 MB
Filnamn:
XA00079CA3_1416.pdf
Memosens data cable CYK10
Safety instructions for electrical apparatus inexplosion-hazardous areas UK Ex II 1 G Ex ia IIC T3/T4/T6 Ga
Språk:
Engelska
Version:
08/12/2021
Filstorlek:
499.6 KB
Filnamn:
XA02783CEN_0121-00.pdf
Memosens data cable Safety instructions for electrical apparatus in explosion-hazardous areas
EN
SV
Kinesiska
12/11/2024
29/03/2022
Språk:
Engelska
Version:
12/11/2024
Filstorlek:
602.5 KB
Filnamn:
XA02845CEN_0224-00.pdf
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safetyinstructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN
SV
Tyska French Polska
22/02/2016
04/03/2015
14/01/2013
21/10/2010
01/12/2006
Språk:
Engelska
Version:
22/02/2016
Filstorlek:
4.3 MB
Filnamn:
XA00376CA3_1616.pdf
Mätkabel CYK10 Tillägg till BA00118C Säkerhetsinstruktioner för elektrisk utrustning som används i explosionsfarliga områden ATEX II 1G Ex ia IIC T3/T4/T6 Ga IECEx Ex ia IIC T3/T4/T6 Ga
EN
SV
Bulgariska Tjeckiska Danska Tyska Grekiska Spanska Estniska Finska French Kroatiska Ungerska Italienska Lithuanian Latvian Holländska Polska Portugisiska Rumänska Slovakiska Slovenska
14/12/2021
Språk:
Svenska
Version:
14/12/2021
Filstorlek:
514.2 KB
Filnamn:
XA02800CSV_0121-00.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
No spare parts available.
Vi värdesätter din integritet
Vi använder cookies för att förbättra din användarupplevelse, samla in statistik för att optimera webbplatsens funktionalitet och leverera skräddarsydda annonser eller innehåll.
Välj "Acceptera alla", för att samtycka till vår användning av cookies.
För mer information se vår Cookie Policy .
Anpassa
Acceptera endast det väsentliga
Acceptera alla