En överblick över specifikationer
-
Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r. -
Measuring range
Gas: 0.3 m/s to 40 m/s
-
Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell -
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
-
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L, Titan Grade 2
Applikationsområde
For a wide range of gas applications Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. A pressure-rated sensor housing with rupture disc limits safety risks. The innovative remote transmitter maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables compliance and process safety at all times.
The measuring principle is unaffected by gas composition
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.
Device properties:
Direct measurement: flow, pressure & temperature
Wetted parts: titanium / 316L
Maximum measuring accuracy: 0.5 %
Remote version with up to 4 I/Os
Backlit display with touch control and WLAN access
Standard cable between sensor and transmitter
Fördelar
Flexible device with user-definable gas mixtures for demanding measuring tasks
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate
High-performance process control – real-time pressure- and temperature-compensated values
Efficient solution – multivariable, no pressure loss
Full access to process and diagnostic information – numerous, freely combinable I/Os
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videor
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
-
Användarinstruktion (BA)
BA Proline Prosonic Flow G 500
Engelsk version - 01/2024
Ultrasonic time-of-flight flowmeter Modbus RS485
EN SV 31/01/202416/09/201905/08/2019Språk:
Engelska
Version:
31/01/2024
Filstorlek:
7.3 MB
Filnamn:
BA01837DEN_0324-00.pdf
-
-
-
Teknisk information (TI)
TI Proline Prosonic Flow G 500
Ultrasonic time-of-flight flowmeter
EN SV 31/01/202416/09/201905/08/2019Språk:
Engelska
Version:
31/01/2024
Filstorlek:
6.1 MB
Filnamn:
TI01386DEN_0324-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Prosonic Flow G 500
Ultrasonic time-of-flight flowmeter
HARTEN SV 31/01/202416/09/201905/08/2019Språk:
Engelska
Version:
31/01/2024
Filstorlek:
7.9 MB
Filnamn:
BA01836DEN_0324-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Prosonic Flow G 500
Ultrasonic time-of-flight flowmeter
Modbus RS485EN SV 31/01/202416/09/201905/08/2019Språk:
Engelska
Version:
31/01/2024
Filstorlek:
7.3 MB
Filnamn:
BA01837DEN_0324-00.pdf
-
-
-
Enhetsparameter (GP)
GP Proline Prosonic Flow G 500
Ultrasonic time-of-flight flowmeter
HARTEN SV 31/01/202405/08/2019Språk:
Engelska
Version:
31/01/2024
Filstorlek:
2.4 MB
Filnamn:
GP01132DEN_0224-00.pdf
-
-
-
Enhetsparameter (GP)
GP Proline Prosonic Flow G 500
Ultrasonic time-of-flight flowmeter
Modbus RS485EN SV 31/01/202405/08/2019Språk:
Engelska
Version:
31/01/2024
Filstorlek:
2.8 MB
Filnamn:
GP01133DEN_0224-00.pdf
-
-
-
Kortfattad instruktion (KA)
KA Proline 500 – digital
Modbus RS485-transmitter
med ultraljudssensor för time of flight-mätningEN SV 31/01/202405/08/2019Språk:
Svenska
Version:
31/01/2024
Filstorlek:
1.7 MB
Filnamn:
KA01378DSV_0224-00.pdf
-
-
-
Kortfattad instruktion (KA)
KA Flödesmätare Proline Prosonic Flow G
Ultraljudssensor för time of flight-mätning
EN SV 31/01/202405/08/2019Språk:
Svenska
Version:
31/01/2024
Filstorlek:
950.6 KB
Filnamn:
KA01374DSV_0224-00.pdf
-
-
-
Kortfattad instruktion (KA)
KA Proline 500 – digital
HART-transmitter
med ultraljudssensor för time of flight-mätningEN SV 31/01/202405/08/2019Språk:
Svenska
Version:
31/01/2024
Filstorlek:
1.3 MB
Filnamn:
KA01377DSV_0224-00.pdf
-
-
-
Installationsanvisningar (EA)
Replacing the transmitter Installation Instructions
Prosonic Flow 500-digital
EN SV 05/08/2019Språk:
Engelska
Version:
05/08/2019
Filstorlek:
324.5 KB
Filnamn:
EA01264DA2_0119.pdf
-
-
-
Installationsanvisningar (EA)
EA Replacing the Components for the Transmitter
Proline 400, 800 Index C, 500-digital
EN SV 01/01/202415/12/202101/11/202101/04/202101/06/2020Språk:
Engelska
Version:
01/01/2024
Filstorlek:
2 MB
Filnamn:
EA01094DA2_1223-00.pdf
-