En överblick över specifikationer
-
Max. process pressure (static)
500 bar (7252 psi)
-
Maximum standard immersion length
900 mm (35,43")
-
Max. immersion length on request
5.000 mm (196,85")
Applikationsområde
Due to the challenging process conditions by heavy duty applications the load capacity of a thermowell must be calculated exactly. Dye penetration tests, ultrasound test, helium leakage test, pressure endurance test as well as various, non-destructive material tests prove the quality of materials and processing.
TA562 is designed for use with resistance and thermocouple thermometers mainly in heavy duty applications.
Fördelar
The thermowell stem shape can be straight or reduced for fast response time
Extension, immersion length and reduced length as well as the bar dimensions can be chosen according to process requirements
Different grades of surface finishing are also available
The process connections are threaded: ½"NPT, ¾"NPT, G½" or M20x1.5
A wide choice of standard materials is available
Special versions can be manufactured according to specification
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
-
Teknisk information (TI)
Technical Information
Omnigrad TA series
Industrial protecting tubesEN SV 26/09/2005Språk:
Engelska
Version:
26/09/2005
Filstorlek:
127.9 KB
Filnamn:
TI138ten.pdf
-
-
-
Teknisk information (TI)
Technical Information Industrial thermowell Omnigrad TA562
Heavy duty -General purpose
From hexagonal bar stock - Threaded process connections
Also DuPont SR1T/SR2TEN SV 19/09/201201/10/1997Språk:
Engelska
Version:
19/09/2012
Filstorlek:
362 KB
Filnamn:
TI00230TEN_1312.pdf
-
-
-
Användarinstruktion (BA)
Thermowells
Operating instructions for thermowells for EAC approval
EN SV 01/12/2016Språk:
Engelska
Version:
01/12/2016
Filstorlek:
1.3 MB
Filnamn:
BA01469TEN_0116.pdf
-
-
-
Specialdokumentation (SD)
Device viewer
Technical documentation in other languages
Språk:
Engelska
Version:
14/07/2021
Filstorlek:
478.5 KB
Filnamn:
SD02429R09EN_0121.pdf
-
-
-
Verksamhetsområden (FA)
Temperaturmesstechnik
Thermometer und Transmitter für die Prozessindustrie
Språk:
Tyska
Version:
17/05/2023
Filstorlek:
17.9 MB
Filnamn:
FA00006Tde_2223_online.pdf
-
-
-
Verksamhetsområden (FA)
Misura della temperatura
Misura della temperatura
Termometri e trasmettitori per l'industria di processoSpråk:
Italienska
Version:
09/07/2024
Filstorlek:
20.3 MB
Filnamn:
FA00006Tit_2223.pdf
-
-
-
Verksamhetsområden (FA)
Misura della temperatura
Termometri e trasmettitori per l'industria di processo
Språk:
Italienska
Version:
17/02/2020
Filstorlek:
30.6 MB
Filnamn:
FA00006TIT_2020.pdf
-
-
-
Verksamhetsområden (FA)
温度計
プロセス産業向けの温度計
および伝送器Språk:
Japanska
Version:
17/02/2020
Filstorlek:
38.9 MB
Filnamn:
FA00006TJA_2020.pdf
-
-
-
Verksamhetsområden (FA)
Mesure de température
Capteurs et transmetteurs de température pour les industries de process
Språk:
French
Version:
20/12/2019
Filstorlek:
60.9 MB
Filnamn:
FA00006TFR-Mesure de temperature.pdf
-
-
-
Verksamhetsområden (FA)
Temperature measurement
Thermometers and transmitters for the process industry
Språk:
Engelska
Version:
17/05/2023
Filstorlek:
18 MB
Filnamn:
FA00006Ten_2223_online.pdf
-