En överblick över specifikationer
-
Max. measurement error
Volume flow (standard):
- ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s) -
Measuring range
0.5 to 10 m/s (1.6 to 33 ft/s)
-
Medium temperature range
-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional -
Max. process pressure
PN 40 / ASME Cl. 300 / JIS 20K
-
Wetted materials
Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432
Applikationsområde
Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry
Device properties:
Full compliance according to NACE MR0175 and MR0103
Nominal diameter: DN 25 to 300 (1 to 12")
Medium temperature: –40 to 200 °C (–40 to 392 °F)
Device as compact or remote version
2-line backlit display with push buttons
HART, PROFIBUS PA, FOUNDATION Fieldbus
Fördelar
Safe design for process industries – international hazardous area approvals
No additional pressure loss – full-bore design
Process transparency – diagnostic capability
Easy installation and reduced installation costs – loop-powered transmitter
Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI
Automatic recovery of data for servicing
Videor
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
-
Teknisk information (TI)
Proline Prosonic Flow 92F Technical Information (SI units)
Engelsk version - 11/2010
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
EN SV 05/11/201004/02/200901/06/2006Språk:
Engelska
Version:
05/11/2010
Filstorlek:
1.4 MB
Filnamn:
TI00073DEN_1310.pdf
-
-
-
Användarinstruktion (BA)
Proline Prosonic Flow 92F Operating Instructions
Engelsk version - 11/2010
Ultrasonic Flow Measuring System
EN SV 05/11/201001/06/2006Språk:
Engelska
Version:
05/11/2010
Filstorlek:
3.5 MB
Filnamn:
BA00121DEN_1310.pdf
-
-
-
Teknisk information (TI)
Proline Prosonic Flow 92F Technical Information (SI units)
Ultrasonic Flow Measuring System, 2-Wire loop powered inline, flowmeter
EN SV 05/11/201004/02/200901/06/2006Språk:
Engelska
Version:
05/11/2010
Filstorlek:
1.4 MB
Filnamn:
TI00073DEN_1310.pdf
-
-
-
Användarinstruktion (BA)
Proline Prosonic Flow 92F FOUNDATION Fieldbus Operating Instructions
Ultrasonic Flow Measuring System
EN SV 08/11/201001/02/2008Språk:
Engelska
Version:
08/11/2010
Filstorlek:
3.3 MB
Filnamn:
BA00128DEN_1310.pdf
-
-
-
Användarinstruktion (BA)
Prosonic Flow 92F PROFIBUS PA Operating Instructions
Ultrasonic Flow Measuring System, 2-Wire loop powered inline
flowmeterEN SV 11/11/201001/06/2006Språk:
Engelska
Version:
11/11/2010
Filstorlek:
3.6 MB
Filnamn:
BA00122DEN_1310.pdf
-
-
-
Användarinstruktion (BA)
Proline Prosonic Flow 92F Operating Instructions
Ultrasonic Flow Measuring System
EN SV 05/11/201001/06/2006Språk:
Engelska
Version:
05/11/2010
Filstorlek:
3.5 MB
Filnamn:
BA00121DEN_1310.pdf
-
-
-
Kortfattad instruktion (KA)
Proline Prosonic Flow 92F Brief Operating Instructions
Ultrasonic flow measuring system
Two-wire inline flowmeterEN SV 01/09/2009Språk:
Svenska
Version:
01/09/2009
Filstorlek:
474.6 KB
Filnamn:
KA00038DSV_0909.pdf
-
-
-
Installationsanvisningar (EA)
EA Replacing cover and O-ring
Proline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN SV 15/10/202401/10/201828/06/2012Språk:
Engelska
Version:
15/10/2024
Filstorlek:
797.3 KB
Filnamn:
EA00098DA2_1624-00.pdf
-
-
-
Installationsanvisningar (EA)
EA Installing sensor parts
Prosonic Flow 92F, Prowirl 72, 73, 200
EN SV 16/10/202301/09/201714/01/201628/11/2013Språk:
Engelska
Version:
16/10/2023
Filstorlek:
2 MB
Filnamn:
EA01085DA2_0423-00.pdf
-
-
-
Installationsanvisningar (EA)
Repair kit cover remote version Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, CNGmass DCI,
Cubemass DCI, Prosonic Flow 92 F, t-mass 65EN SV 01/10/201813/11/201418/04/2014Språk:
Engelska
Version:
01/10/2018
Filstorlek:
216.9 KB
Filnamn:
EA01108DA2_0318.pdf
-
-
-
Installationsanvisningar (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN SV 01/03/201828/11/201325/04/2013Språk:
Engelska
Version:
01/03/2018
Filstorlek:
139.5 KB
Filnamn:
EA01051DA2_0318.pdf
-
-
-
Installationsanvisningar (EA)
Replacing transmitter parts
Prowirl 72, 73, Prosonic Flow 92
EN SV 03/03/202001/04/201913/12/2010Språk:
Engelska
Version:
03/03/2020
Filstorlek:
451.5 KB
Filnamn:
EA00043DA2_1520.pdf
-