En överblick över specifikationer
-
Measured variables
Corg
-
Ambient temperature range
+5 °C ... +40 °C
-
Process pressure
–120 hPa ... 120 hPa
Relative
Applikationsområde
The GMS800 FIDOR extractive gas analyzer is ideally suited for emission measurements according to regulatory requirements. Based on the proven flame ionization detection principle, the GMS800 FIDOR measures total hydrocarbon concentrations in gases at both trace levels and high concentration levels. The different housinga makes stand-alone operation and integration into existing systems such as the MCS200HW multi-component analyzer very easy.
Monitoring of hydrocarbon emissions in raw gas and clean gas
Emissions measurement in thermal, catalytic, and biological exhaust gas cleaning systems
Laboratory applications
Device properties:
Standard 19” enclosure for easy integration into all industry-typical systems
Space-saving wall housing (stand-alone)
Nearly maintenance free ejector pump
Automatic regulation and compensation of process pressure fluctuations
High degree of linearity (≤ 2 %) for very low and high measuring ranges
Fördelar
Very high availability
Convenient remote diagnosis and operation via Ethernet using SOPAS-ET software
Replacement of complete assemblies and modules makes repairs easy
Hydrogen as fuel gas, expensive helium is not required
Low operating costs, e.g., due to low hydrogen consumption
The GMS811 FIDOR version, on which the BCU control unit can be separated from the analyzer unit, supports convenient control and monitoring from a central control room
Xpert urvalet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
-
Branschlösning (SO)
Oil and gas – solutions for the oil and gas industry
Endress+Hauser offers the best solutions through a huge range of products and systems to measure and perform even under the most
rigorous operating conditions.Språk:
Engelska
Version:
01/01/2025
Filstorlek:
3.3 MB
Filnamn:
8030418_SO_Ol_and_Gas_en_ V1-0_2025.01_EHS.pdf
-
-
-
Kompetensbroschyr (CP)
Emission Monitoring Solutions – broad instrument portfolio and longstanding experience
An overview brochure about emission monitoring, their measuring
principles and technologies, global requirements and services, a
selection guide and the measuring devices at a glanceSpråk:
Engelska
Version:
01/01/2025
Filstorlek:
4.5 MB
Filnamn:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
-
-
-
Innovation (IN)
GMS800 FIDOR – total hydrocarbon analyzer
Based on the proven flame ionization detection principle, the GMS800
FIDOR measures total hydrocarbon concentrations in gases at
both trace levels and high concentration levels.Språk:
Engelska
Version:
01/01/2025
Filstorlek:
3.2 MB
Filnamn:
8029985_IN_GMS800-FIDOR_en_V3-0_2025.01_EHS.pdf
-
-
-
Verifiering DTM
GMS800, FIDOR SDD file
SOPAS device description file for GMS800, FIDOR
Språk:
Language neutral
Version:
05/12/2024
Filstorlek:
10 MB
Filnamn: