En överblick över specifikationer
-
Max. process pressure (static)
40 bar (580 psi)
-
Maximum standard immersion length
48" (1.219 mm)
Applikationsområde
Best applicable for use in hygienic or aseptic pipes and containers or tanks even with very small immersion lengths. It meets increased protection requirements of the temperature sensor regarding physical and chemical effects. Ideally suited to all measuring points that require regular re-calibration by simply replacing the insert in closed processes.
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Pressure range up to 40 bar (580 psi)
For increased protection requirements of the temperature sensor regarding physical and chemical effects
For use in pipes and containers or tanks
Ideally suited to all measuring points that require regular recalibration by simply replacing the insert in closed processes
Fördelar
-
iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration of the insert used
-
All common hygienic process connections
-
International certification: hygiene standards as per 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
-
Fast response time owing to reduced tips with thin walls
-
State of the art Tee and Elbow elements, without welds and dead legs and with best in class hygienic design
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
Föregångare
-
-
Teknisk information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN SV 25/03/202415/09/202328/10/202130/07/202119/06/2020Språk:
Engelska
Version:
25/03/2024
Filstorlek:
1.1 MB
Filnamn:
TI00426FEN_2524.pdf
-
-
-
Teknisk information (TI)
iTHERM TT412
Thermometer thermowell for hygienic and aseptic applications
EN SV 29/07/202213/01/202131/10/201804/08/2017Språk:
Engelska
Version:
29/07/2022
Filstorlek:
1.2 MB
Filnamn:
TI01350TEN_0422-00.pdf
-
-
-
Specialdokumentation (SD)
Device viewer
Technical documentation in other languages
Språk:
Engelska
Version:
14/07/2021
Filstorlek:
478.5 KB
Filnamn:
SD02429R09EN_0121.pdf
-
-
-
Specialdokumentation (SD)
SD Hygienic process connection types
Supplement to TM311, TM371, TM372, TM401, TM411, TM402, TM412, TT411,
TT412, TE411, TK40, TMR35, DTT35, TTR35Språk:
Engelska
Version:
15/09/2023
Filstorlek:
800.3 KB
Filnamn:
SD03119TEN_0123-00.pdf
-
-
-
Tillverkarförsäkran
Product family: Accessories: Pipe thermowell, Accessories: Inserts, PROCESS RTD HYGIENIC, RTD thermometer
Product root: TK40-, TM371-, TM372-, TM401-, TM402-, TM411-,
TM412-, TMR35-, TS111-, TS212-, TT411-, TT412-
Declaration number: HE_00886_01.17
Additional information: TSE compliance, animal fat freeEN SV 23/10/2017Språk:
Engelska
Version:
23/10/2017
Filstorlek:
160.7 KB
Filnamn:
HE_00886_0117.pdf
-
-
-
Tillverkarförsäkran
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: HE_01097_03.24
Manufacturer specification: Food hygieneSpråk:
Engelska
Version:
24/10/2024
Filstorlek:
112.3 KB
Filnamn:
HE_01097_03.24_en.pdf
-
-
-
Tillverkarförsäkran
Product family: Accessories: Pipe thermowell, Magphant, Process RTD hygienic, RTD thermometer
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: HE_00099_05.15
Manufacturer specification: Food hygiene, 10/2011, 1935/2004EN SV 07/12/2020Språk:
Engelska
Version:
07/12/2020
Filstorlek:
1.7 MB
Filnamn:
HE_00099_05.15.pdf
-
-
-
Tillverkarförsäkran
Product family: Accessories: Bar stock thermowell, Accessories: Pipe thermowell, Accessories: Inserts, Magphant, Process RTD general purpose, Process RTD hygienic, RTD thermometer
Product root: DTT31-, DTT35-, TK40-, TM101-, TM111-, TM121-, TM131-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-,
TS111-, TS212-, TT131-, TT151-, TT411-, TT412-
Declaration number: HE_01494_01.21
Manufacturer specification: Food hygiene
Additional information: BSE, TSESpråk:
Engelska
Version:
27/07/2023
Filstorlek:
266 KB
Filnamn:
HE_00886_07_17.pdf
-
-
-
Tillverkarförsäkran
Product family: Process RTD hygienic
Product root: TK40-, TM401-, TM402-, TM411-, TM412-, TS111-,
TS112-, TT411-, TT412-
Declaration number: MD-12028A-9Språk:
Engelska
Version:
10/01/2013
Filstorlek:
872.7 KB
Filnamn:
MD-12028a_09_e.pdf
-
-
-
FDA-försäkran
Product family: Accessories: Pipe thermowell, Magphant, PROCESS RTD HYGIENIC, RTD-THERMOMETER
Product root: DTT35-, TK40-, TM311-, TM371-, TM372-, TM401-,
TM402-, TM411-, TM412-, TMR35-, TT411-, TT412-, TTR35-
Declaration number: FDA_00127_03.17
FDA specification: SealingEN SV 20/07/2020Språk:
Engelska
Version:
20/07/2020
Filstorlek:
450.8 KB
Filnamn:
FDA_00127_03.17.pdf
-