En överblick över specifikationer
-
Max. measurement error
Volume flow:
±3% o.r. for DN15
±2% o.r. for DN25 to 200
±2% o.r. above DN200 -
Measuring range
0 to 15 m/s (0 to 50 ft/s)
-
Medium temperature range
–40 to +130 °C (–40 to +266 °F)
-
Max. process pressure
N/A
Applikationsområde
Prosonic Flow W 400 is the ultrasonic clamp-on flowmeter of choice for safe, cost-effective and maintenance-free measurement of conductive and non-conductive liquids. It measures flow noninvasively and bidirectionally, independent of pressure, density and conductivity, and without process interruption.
FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
Heartbeat Technology provides continuous process transparency with its diagnostic, verification and monitoring functions. This way, build-up can be detected before it affects operation.
Fördelar
Flexible mounting – FlowDC reduces inlet runs to a minimum
Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals
-
Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160")
-
User-friendly operation – the web server offers full remote access, while the device’s display offers convenient on-site interaction
-
Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times
Videor
Extended urvalet
-
High-end produkter
- Mycket funktionella och praktiska
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
Föregångare
-
-
Teknisk information (TI)
TI Proline Prosonic Flow W 400
Engelsk version - 05/2024
Ultrasonic time-of-flight flowmeter
EN SV 15/05/202411/01/2022Språk:
Engelska
Version:
15/05/2024
Filstorlek:
4.1 MB
Filnamn:
TI01568DEN_0224-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Prosonic Flow W 400
Engelsk version - 05/2024
Ultrasonic time-of-flight flowmeter Modbus RS485
EN SV 15/05/2024Språk:
Engelska
Version:
15/05/2024
Filstorlek:
5.6 MB
Filnamn:
BA02302DEN_0124-00.pdf
-
-
-
Teknisk information (TI)
TI Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
EN SV 15/05/202411/01/2022Språk:
Engelska
Version:
15/05/2024
Filstorlek:
4.1 MB
Filnamn:
TI01568DEN_0224-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
HARTEN SV 15/05/202411/01/2022Språk:
Engelska
Version:
15/05/2024
Filstorlek:
6.5 MB
Filnamn:
BA02086DEN_0224-00.pdf
-
-
-
Användarinstruktion (BA)
BA Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
Modbus RS485EN SV 15/05/2024Språk:
Engelska
Version:
15/05/2024
Filstorlek:
5.6 MB
Filnamn:
BA02302DEN_0124-00.pdf
-
-
-
Enhetsparameter (GP)
GP Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
HARTEN SV 15/05/202411/01/2022Språk:
Engelska
Version:
15/05/2024
Filstorlek:
2.1 MB
Filnamn:
GP01167DEN_0224-00.pdf
-
-
-
Enhetsparameter (GP)
GP Proline Prosonic Flow W 400
Ultrasonic time-of-flight flowmeter
Modbus RS485EN SV 15/05/2024Språk:
Engelska
Version:
15/05/2024
Filstorlek:
2.3 MB
Filnamn:
GP01207DEN_0124-00.pdf
-
-
-
Kortfattad instruktion (KA)
KA Proline 400
Transmitter med ultraljudssensor för time of flight-mätning
HARTEN SV 15/05/202411/01/2022Språk:
Svenska
Version:
15/05/2024
Filstorlek:
2.7 MB
Filnamn:
KA01510DSV_0224-00.pdf
-
-
-
Kortfattad instruktion (KA)
KA Proline Prosonic Flow W
Ultraljudssensor för time of flight-mätning
EN SV 15/05/202411/01/2022Språk:
Svenska
Version:
15/05/2024
Filstorlek:
1.2 MB
Filnamn:
KA01512DSV_0224-00.pdf
-
-
-
Kortfattad instruktion (KA)
KA Proline 400
Transmitter med ultraljudssensor för time of flight-mätning
Modbus RS485EN SV 15/05/2024Språk:
Svenska
Version:
15/05/2024
Filstorlek:
1.7 MB
Filnamn:
KA01660DSV_0124-00.pdf
-
-
-
Installationsanvisningar (EA)
EA Replacing Small Parts
Proline 10, 400, 500, 500-digital, 800 Index B, 800 Index C, Cubemass
EN SV 01/01/202415/12/202101/05/202101/04/202101/06/2020Språk:
Engelska
Version:
01/01/2024
Filstorlek:
1.2 MB
Filnamn:
EA01024DA2_1223-00.pdf
-
-
-
Installationsanvisningar (EA)
Replacing the sensor cable
Prosonic Flow 400
EN SV 15/12/2021Språk:
Engelska
Version:
15/12/2021
Filstorlek:
662.5 KB
Filnamn:
EA01406DA2_0121-00.pdf
-