En överblick över specifikationer
-
Measuring range
Conductivity:
0 µS/ cm...100 mS/ cm
Build-up thickness:
0 mm…10 mm -
Process temperature
-20°C…+100°C
(-4°F...+212°F)
+150°C (+302°F) for 1h -
Process pressure
Vacuum...25 bar
(Vacuum...362.5 psi) -
Measuring method
Capacitive- conductive
Applikationsområde
The Liquitrend QMW43 is developed for the food and beverage industry to help customers to ensure product safety, improve quality and increase the availability of installations. Base your decisions on the unique and reliable measurement of buildup thickness and conductivity via the combination of conductive and capacitive measuring modes.
Cleaning optimization, blending homogeneity monitoring and media differentiation of liquids, suspensions, pasty media etc.
For the use in storage, mixing and process vessels with or without an agitator, pipes and equipment periphery
Process connections: Threads and hygienic connections
Sensor design: Flush-mounted, surface roughness Ra<0.76µm
Temperature: -20 to +100°C (-4 to +212°F), CIP/SIP to 150°C (302°F) for 1 hour
Certificates and declarations: 3A, FDA, EHEDG and EG1935/2005, EN10204- 3.1
Fördelar
-
Reliable, repeatable and accurate measurement of buildup thickness and conductivity regardless of media type
-
Conductive as well as capacitive measuring cycles, the device automatically detects the most accurate measuring mode and uses it automatically
-
Verification of cleaning status without the need to open the tank
-
Compact and flush-mounted stainless-steel sensor offers the perfect insight into the conditions in pipelines or tanks at all critical locations
-
Plug and Play - simple commissioning without presettings
-
Hygienic safety by Design and material traceability are a matter of course
-
Integrated digital communication option via IO-Link
Videor
Lean urvalet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
-
-
Teknisk information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN SV 25/03/202415/09/202328/10/202130/07/202119/06/2020Språk:
Engelska
Version:
25/03/2024
Filstorlek:
1.1 MB
Filnamn:
TI00426FEN_2524.pdf
-
-
-
Teknisk information (TI)
Liquitrend QMW43
Conductive and capacitive measurement
EN SV 18/12/2019Språk:
Engelska
Version:
18/12/2019
Filstorlek:
392.9 KB
Filnamn:
TI01419FEN_0119.pdf
-
-
-
Användarinstruktion (BA)
Liquitrend QMW43
Conductive and capacitive measurement of conductivity and thickness of
buildupEN SV 18/12/2019Språk:
Engelska
Version:
18/12/2019
Filstorlek:
548.1 KB
Filnamn:
BA01925FEN_0118.pdf
-
-
-
Kortfattad instruktion (KA)
Liquitrend QMW43
Konduktiv och kapacitiv mätning av konduktivitet och avlagringars
tjocklekEN SV 18/12/2019Språk:
Svenska
Version:
18/12/2019
Filstorlek:
369.7 KB
Filnamn:
KA01448FSV_0119.pdf
-
-
-
Kortfattad instruktion (KA)
KA Liquitrend QMW43
Konduktiv och kapacitiv mätning av konduktivitet och avlagringars
tjocklekEN SV 01/09/2022Språk:
Svenska
Version:
01/09/2022
Filstorlek:
336.4 KB
Filnamn:
KA01595FSV_0122-00.pdf
-
-
-
ZE (certifikat)
Liquitrend QMW43
Konformitätserklärung / Declaration of Compliance
Liquitrend QMW43EN SV 15/07/2019Språk:
Engelska
Version:
15/07/2019
Filstorlek:
973.5 KB
Filnamn:
ZE01055FA2_0119.pdf
-
-
-
Specialdokumentation (SD)
SD M12 socket
Accessories for devices with M12 plug
EN SV 30/06/202329/05/2020Språk:
Engelska
Version:
30/06/2023
Filstorlek:
289.2 KB
Filnamn:
SD02586FEN_0223-00.pdf
-
-
-
Specialdokumentation (SD)
Application conditions for seals and plastics in the food sector Level measurement, pressure measurement Special Documentation
Application conditions for seals and plastics in the food sector
EN SV 23/07/2019Språk:
Engelska
Version:
23/07/2019
Filstorlek:
97.6 KB
Filnamn:
SD02430FEN_0119.pdf
-
-
-
Specialdokumentation (SD)
SD Hygiene certificates
Level and pressure measuring devices
EN SV 07/05/202427/09/202315/12/202129/01/202105/06/2020Språk:
Engelska
Version:
07/05/2024
Filstorlek:
564.2 KB
Filnamn:
SD02503FEN_0624-00.pdf
-
-
-
Specialdokumentation (SD)
SD Endress+Hauser IO-Link devices
Endress+Hauser IO-Link function blocks
For Siemens TIA PortalEN SV 01/12/2024Språk:
Engelska
Version:
01/12/2024
Filstorlek:
4.2 MB
Filnamn:
SD03368SEN_0124-00.pdf
-