Ramanspektroskopi – avancerad optisk analysteknik
Förbättra anläggningssäkerheten, säkerställ produktkvaliteten och optimera driften. Ramanspektroskopi mäter sammansättningen och molekylstrukturen i dina prover från labb till process i realtid.
Produkten är inte tillgänglig på den svenska marknaden.
Temperature: probe is non-contact; operating temp: 10 to 50 °C / 50 to 122 °F
The union between our Raman analyzers equipped with Rxn-46 bioprocess probe technology and the BioPAT® Spectro platform by Sartorius offers the market an ideal interface to high-throughput development through single-use commercial manufacturing. Our Raman bioprocessing probe technology has been adapted to fit Sartorius’s BioPAT® Spectro platform, utilizing the same probe design for Ambr® 15, Ambr® 250, & Biostat STR® bioreactors.
Cell culture: glucose, lactate, amino acids, cell density, titer, and more
Enables faster, easier, and more robust model building via integration with Ambr® 15 and Ambr® 250
Allows high-throughput process development which supports QbD
Provides a more efficient transfer to Biostat STR® for single-use manufacturing
Offers a scale-independent interface from 15 ml in the laboratory to 2000 L in the production suite
Requires no probe cleaning, sterilization, or frequent maintenance due to non-contact sampling
High-end produkter
Tekniska egenskaper
Enkelhet
Standardprodukter
Tekniska egenskaper
Enkelhet
Specialprodukter
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
System design and specifications for the Raman Rxn-46 probe
Språk: |
Engelska |
Version: |
11/01/2024 |
Filstorlek: |
353.8 KB |
Filnamn: |
TI01634CEN_0324.pdf |
System design and specifications for the Raman Rxn-46
calibration and verification kit
Språk: |
Engelska |
Version: |
11/01/2024 |
Filstorlek: |
400.4 KB |
Filnamn: |
TI01765CEN_0123.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-46 probe
Språk: |
Engelska |
Version: |
11/01/2024 |
Filstorlek: |
860.2 KB |
Filnamn: |
BA02170CEN_0324.pdf |
Commissioning, operation, and maintenance details for the
Raman Rxn-46 calibration and verification kit
Språk: |
Engelska |
Version: |
11/01/2024 |
Filstorlek: |
928.9 KB |
Filnamn: |
BA02324CEN_0123.pdf |
Quick start guide for the Raman Rxn-46 probe
Språk: |
Engelska |
Version: |
11/01/2024 |
Filstorlek: |
534.7 KB |
Filnamn: |
KA01550CEN_0324.pdf |
A Q&A about how our Raman spectroscopy analyzer systems
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
and Rxn-46 probe), powered by Kaiser Raman technology, integrates
with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for
high throughput and single use (SUB) bioprocessingin the
biopharmaceutical life science industry.
Språk: |
Engelska |
Version: |
08/12/2021 |
Filstorlek: |
943.7 KB |
Filnamn: |
PU01446CEN_0121.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
Språk: |
Engelska |
Version: |
19/04/2022 |
Filstorlek: |
1.1 MB |
Filnamn: |
PU01447CEN_0222.pdf |
An overview of the Raman calibration and verification kits for
the bio multi optic / single use optic and the Raman flow assembly
(includes the flow bench and flow cell). These kits are to be used in
conjunction with the Rxn-10 probe and Raman Rxn2 / Rxn4 analyzer
for upstream and downstream bioprocessing (powered by Kaiser
Raman technology).
Språk: |
Engelska |
Version: |
13/12/2023 |
Filstorlek: |
2.1 MB |
Filnamn: |
PU01518CEN_0223.pdf |
A combined product list of analysis offerings from both Optical Analysis
and LIquid Analysis for bioprocessing applications in the life science
industry (including Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Rxn-10 probe, bio multi optic and bio sleeve, Raman flow assembly,
Rxn-45 probe, Rxn-46 probe, Raman optic system for single use,
Memosens CPS61E, Memosens COS81E, OUSBT66, Memosens CPS61E,
Memosens CPS77E, Memosens CLS82E, OUSAF44, Memosens CPS11E,
Memosens CLS16E, TOC Analyzer CA79, Liquiline transmitter platform, and
Memobase software).
Språk: |
Engelska |
Version: |
11/04/2024 |
Filstorlek: |
776.1 KB |
Filnamn: |
PU01484CEN_0224.pdf |
ラマン分光法プローブ製品ラインナップに関する概要パンフレットです。
この製品ラインナップには、Rxn-10プローブ、Rxn-20プローブ、Rxn-30プローブ、
Rxn-40プローブ、Rxn-41プローブ、Rxn-45プローブ、Rxn-46プローブ、
およびプローブオプティクアクセサリ(bIOオプティック、
シングルユース向けラマンオプティックシステム/SUB、浸漬オプティック、
非接触オプティック)が含まれています。
これらはすべて、Kaiserラマンテクノロジーによって動作します。
Språk: |
Japanska |
Version: |
24/06/2024 |
Filstorlek: |
5.4 MB |
Filnamn: |
IN01225CJA_0121_Raman_spectroscopic_probes.pdf |