En överblick över specifikationer
-
Accuracy
+/- 2mm + 0.17% of measured distance
Applikationsområde
Prosonic FMU90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids. Also the flow measurement in open channels and weirs is possible as the simultaneous measurement of level and flow in a storm water overflow basin with only 1 sensor. Up to 6 relays for tendency alarm, flow pulse output or backwater/sludge alarm, 1 or 2 channel version.
Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection. Pump control, rake control and as option: additional pump control function.
Calculations: Average, difference, sum
Application flow: Flow measurement in open channels and weirs with 1 or 2 sensors
Flow measurement with back water or sludge detection
Up to 3 totalizers and 3 counters
Counting or time pulse output for control of external units
Fördelar
Simple, menu-guided operation with 6-line plain text display, 15 languages selectable
Envelope curves on the display for quick and simple diagnosis
Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program
Time-of-Flight correction via integrated or external temperature sensors
Linearisation (up to 32 points, freely configurable) for the most common flumes and weirs
pre-programmed and selectableOnline calculation of the flume-/weir-flows via integrated flow curves
Automatic detection of the sensors FDU9x
Videor
Xpert urvalet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
-
Standardprodukter
- Pålitliga, robusta och lätta att underhålla
Tekniska egenskaper
Enkelhet
-
Specialprodukter
- Designade för krävande applikationer
Tekniska egenskaper
Enkelhet
Varierande
FLEX urvalet | Tekniska egenskaper | Enkelhet |
---|---|---|
Fundamental urvalet Möt dina grundläggande mätbehov |
Tekniska egenskaper
|
Enkelhet
|
Lean urvalet Hantera dina kärnprocesser med enkelhet |
Tekniska egenskaper
|
Enkelhet
|
Extended urvalet Optimera dina processer med innovativa teknologier |
Tekniska egenskaper
|
Enkelhet
|
Xpert urvalet Hantera dina mest utmanande applikationer |
Tekniska egenskaper
|
Enkelhet
Varierande |
Föregångare
-
-
Teknisk information (TI)
Prosonic S FMU90
Engelsk version - 05/2021
Ultrasonic measuring technology
EN SV 31/05/202124/08/202021/03/201712/08/201622/03/2013Språk:
Engelska
Version:
31/05/2021
Filstorlek:
1.3 MB
Filnamn:
TI00397FEN_1921.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90 HART
Engelsk version - 05/2021
Ultrasonic measuring technology Level measurement 1 or 2 sensors
EN SV 31/05/202117/08/202021/03/201702/04/201223/07/2009Språk:
Engelska
Version:
31/05/2021
Filstorlek:
3.3 MB
Filnamn:
BA00288FEN_1621.pdf
-
-
-
Teknisk information (TI)
TI Khafagi-Venturi QV302 to QV316
Flow measurement
EN SV 27/08/202418/05/2022Språk:
Engelska
Version:
27/08/2024
Filstorlek:
496.2 KB
Filnamn:
TI01681FEN_0224-00.pdf
-
-
-
Teknisk information (TI)
Prosonic S FMU90
Ultrasonic measuring technology
EN SV 31/05/202124/08/202021/03/201712/08/201622/03/2013Språk:
Engelska
Version:
31/05/2021
Filstorlek:
1.3 MB
Filnamn:
TI00397FEN_1921.pdf
-
-
-
Teknisk information (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN SV 25/03/202415/09/202328/10/202130/07/202119/06/2020Språk:
Engelska
Version:
25/03/2024
Filstorlek:
1.1 MB
Filnamn:
TI00426FEN_2524.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90 PROFIBUS DP
Ultrasonic measuring technology
Level measurement
1 or 2 sensorsEN SV 31/05/202117/08/202002/04/201223/07/200906/04/2009Språk:
Engelska
Version:
31/05/2021
Filstorlek:
3.2 MB
Filnamn:
BA00292FEN_1621.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90
Slot-Index Lists for PROFIBUS DP
EN SV 02/04/201230/04/200726/06/2006Språk:
Engelska
Version:
02/04/2012
Filstorlek:
6.2 MB
Filnamn:
BA00333FEN_1312.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90 HART
Ultrasonic measuring technology
Level measurement
1 or 2 sensorsEN SV 31/05/202117/08/202021/03/201702/04/201223/07/2009Språk:
Engelska
Version:
31/05/2021
Filstorlek:
3.3 MB
Filnamn:
BA00288FEN_1621.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90 HART
Ultrasonic measuring technology
Flow measurement
1 or 2 sensorsEN SV 31/05/202117/08/202002/04/201223/07/200906/04/2009Språk:
Engelska
Version:
31/05/2021
Filstorlek:
3.1 MB
Filnamn:
BA00289FEN_1621.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90
Ultrasonic Transmitter
EN SV 02/04/201223/07/200914/01/200805/05/200702/03/2007Språk:
Engelska
Version:
02/04/2012
Filstorlek:
3 MB
Filnamn:
BA00290FEN_1312.pdf
-
-
-
Användarinstruktion (BA)
Prosonic S FMU90 PROFIBUS DP
Ultrasonic measuring technology
Flow measurement
1 or 2 sensorsEN SV 31/05/202117/08/202002/04/201223/07/200906/04/2009Språk:
Engelska
Version:
31/05/2021
Filstorlek:
3.1 MB
Filnamn:
BA00293FEN_1621.pdf
-
-
-
Enhetsparameter (GP)
Prosonic S FMU90
Level measurement
Flow measurement over open channelsEN SV 31/08/2020Språk:
Engelska
Version:
31/08/2020
Filstorlek:
1.7 MB
Filnamn:
GP01151FEN_0120.pdf
-